Change the control settings of the method, the response as soon as possible in the process of the system lags behind, be the smallest system overshoot. Controlled by two PID (PID is a variable in each group) control loop structure, known as the two sets of control loops: the main circuit and......
Chat Now

dynamic-temp-control.jpg

Change the control settings of the method, the response as soon as possible in the process of the system lags behind, be the smallest system overshoot. Controlled by two PID (PID is a variable in each group) control loop structure, known as the two sets of control loops: the main circuit and from the circuit, the main control loop from the loop output as the settings.

Type

Temp range℃

Heating KW

Cooling capacity  KW  AT  ℃

Flow/pressure
L/min bar

Outside size

Power

180

50

0

-5

-20

-35

SUNDI-320

-30~+180

2

1.5

1.5

1.5

0.9

0.6


10

0.8

400*600*800

2.9kw

SUNDI-420W

-40~+180

2

1.8

1.8

1.8

1.2

1

0.3

10

0.8

400*600*800

3.3kw

Type

SUNDI/UST series

Control Mode

Feedback PID + Our special dynamic control calculation, Lneya PLC controller

Temp.control

Material reaction temp.control mode and jacket temp.control mode

Program Editor

10 programs, each program can edit 45 steps.

Communication Portocol

MODBUS RTU Protocol,RS485 interface

Optional  Ethernet interface/R232 interface

Temp.feedback

The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor

Material temp. feedback

Material temp. feedback:PT100 or 4~20mA or communication given

Temp.feedback:PT100

Temp. difference

Set or control oil outlet temp and reactor material temp. difference

Set or control equipment liquid inlet temp. And liquid outlet temp. Difference( keep system safe)

Material temp.accuracy

±1℃ (sometimes ±0.5℃)

Thermal medium temp. accuracy

±0.5℃

Closed circulation system

The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.

heating

 Heating max output power

 The heater has triple protection and independent temperature limiter to ensure the safety of heating system.

The power is greater than 15KW with a voltage regulator, and the heating power output control adopts 4-20ma linear control.

Cooling capacity

The power of taking away the heat at different temperature

Circulation flow rate and pressure

  Lower than 75L/min, use Lneya Magnetic pump

Higher than 75L/min use Ultra wide temperature high energy efficiency centrifugal pump.

  Pressure selection: 2bar 3bar 5bar 8bar(small power equipment can not customize)

 The greater the pressure, the greater the power of the motor, which will increase the system load and reduce the cooling capacity of the system.

compressor

Different type different brand compress

Mitsubishi, skop, Emerson, Danfoss, Italy Dorin, German blog, bizell, French Tecumseh.

evaporator

KAORIPlate heat exchanger

Oil separator

Emerson/Lneya

Drying filter

danfoss/Emerson

Shock tube

CASTEL/packless

voltage-controlled

danfoss/Emerson/fengsheng

Expansion valve

Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.

Select different expansion valves with different temperature and cooling capacity.


Operation panel

Lneya 7-inch touch screen,show temp curve\EXCEL data output

1、Optional Siemens explosion - proof touch screen.(Place the operation panel outside the site area.)

2、optional GMP, FDA operation and record module (operator use record, data record, alarm record, etc.)

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.

refrigerant

R-404A / R404A R23 mixture/ R404A R23 R14 mixture

interface size

G1/2、G3/4、G1、DN25 DN32 DN40 DN50 DN65 DN80 DN100(PN10 RF)

Water-cooling W

 With W is water cooled type, lower than -60 degree equipment, you need use 7-25 degree cooled water

Water cooled condenser.

Tube heat exchanger, plate heat exchanger, tube condenser.

packless、sheng、KAORI、JINDIAN、XIAOLING etc

power

AC 380V 50HZThree-phase five-wire system.  Small power 220V 50HZ single phase

Optional 460V 60HZ、220V 60HZ three-phase  

Shell material

Standard shellSUS 304,optional spraying plastics (color 7035)

Isolation of explosion-proof

optioanl(EXdIIBT4)   

Lneya explosion-proof product installation license number.:PCEC-2017-B025

Positive pressure explosion-proof

optioanl(EXPXdmbIICT4)The positive pressure system must be water-cooled type

Lneya explosion-proof product installation license number:PCEC-2017-B025

Self pressurizing system

Optional self-pressurized 3bar system, the temperature of the system can be expanded, the expansion tank is normal pressure.

KDOC-80 can be used in a pressurized system with a maximum temperature of 250 degrees (-85 degree ~ 250 degree).

KDOC-220 can be used in the self-pressurized system with maximum temperature to 320 degrees (-50 degree ~ 320 degree).

KDOC-210 can be used in a self-pressurized system with a maximum temperature of 300 degrees (-70 degree ~ 300 degree)

Flow/pressure

Optional flow/pressure sensor, display flow and pressure on the touch screen.

Optional control flow/pressure.


One for two system

Optional one for two systems: the costis lower than one to one system.

One unit heating and cooling machine contains two circulation system, two cooling system, two heating systems, one expansion system, one electrical system.

High exothermic control

Customizable high heat control system algorithm and components.

flow reactor temperature control module.

It can be used in the flow reactor temp control system (pump, internal circulation system, control algorithm, refrigeration)

Impact and Solution of Excess Exhaust Temperature of Industrial Chiller Units

Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chiller high pressure and high temperature, overload, reduced working efficiency and poor industrial water chiller compressor refrigerating capacity. It can also lead to other problems. So how to reduce the exhaust temperature of industrial water chillers and cool the compressor, we are the experts to develop water chiller refrigeration system 320/420 w / 430 w experts, so today we will recommend a few solutions for you:

Increase cooling water flow and heat ventilation of water tank and water tower.
Air-cooled water tank of industrial cold water machine and cooling water in industrial cooling towers are to cool the condenser and transfer heat which can take away the heat generated by the compressor work. If you can guarantee the cooling water flow rate and air cooling industry cold water machine water tanks, water chiller water tower cooling ventilation ability, you will keep cooling water temperature to within the limits defined, so as to maximize the cool the compressor.

Reduce the exhaust temperature of the refrigeration compressor directly.
You can start from decreasing compression ratio and the load of the compressor. Lower compression ratio will make compressor low efficient, but it can solve the problem of excess exhaust temperature of
compressor.


Packing & Shipping

Delivery detail:


UPS/DHL/FEDEX/TNT express are available for your choose which take 3~ 5 days to arrive,and  we will offer the tracking number for you to check the status of your items online at any time. 

 By air cargo which takes about one week to arrive .

 By sea which takes about 20-30days to arrive , depending on your actual requirements.

201807271014247792659.png

Our Service

1.Warranty:

12 months warranty for scientz High Throughput Tissuelyser

If any technical problem during warranty time, replacement parts will be sent free of charge.

Technical support is also available in whole time.

2.Our Advantage

1. Reply your enquiry in 24 working hours.

2. Experienced staffs answer all your questions in fluent English.

3. OEM is available if the quantity is large.

4. We offer very competitive for all our products.

3.After-sales

Our machines undergo an extensive and strict testing and quality control procedure, ensuring every item purchased meet global quality standards.It's safe and reliable quality for scientz High Throughput Tissuelyser.


Our Factory

201807271017045486895.jpg

Our Workship

201807271017288797624.jpg

Our Exhibition

201807271017501596687.jpg

Our Activity

201807271018109853535.jpg

Our Certification

201807271018512350073.png


Hot Tags: compressors refrigerators, suppliers, manufacturers, customized, buy discount
  • QR CODE
  • facebook